Conductor | IEC 60228; DIN VDE 0295; EN 60228 Class 2 or Class 5 Electrolytic Bare or Tinned Copper |
Insulation | EN 50290-2-23 PE Compound |
Colour Code | DIN 47100 |
Individual Screen | Pes Tape + Tinned Copper Drain Wire + Pes Tape |
Stranding | Screened pairs in layers |
Wrapping | Pes Tape |
Screen | Tinned Copper Drain Wire + Al-Pes Tape |
Sheath | EN 50290-2-22 PVC Compound |
Sheath Colour | RAL 7001 Grey |
CONDUCTOR RESISTANCE |
INSULATION RESISTANCE (500 V) |
MUTUAL CAPACITY (MAX) |
IMPEDANCE (APPROX.) |
INDUCTANCE (APPROX.) |
CURRENT CARRYING CAPACITY (25°C) |
|||
mm² 0,22 0,34 0,50 0,75 1,0 1,5 2,5 |
Ω/km 79 56 39 26 19,5 13,3 7,98 |
5000MΩxkm | mm² 0,22 0,34 0,50 0,75 1,0 1,5 2,5 |
Ω/km pF/m 70 80 90 90 90 100 120 |
78Ω | 0,67mH/km | mm² 0,22 0,34 0,50 0,75 1,0 1,5 2,5 |
A 2,5 4,5 6,0 13 16 20 25 |
OPERATING VOLTAGE |
TEST VOLTAGE |
BENDING RADIUS |
TEMPERATURE RANGE |
FLAME RETARDANT TEST |
0,22/0,34mm2 = 250V >0,50mm2 = 300/500V |
0,22/0,34mm2 = 1500V 0,50mm2 = 2000V |
10x Cable Ø | -30ºC+70ºC | IEC 60332-1-2 VDE 0482-322-1-2 EN 60332-1-2 |
LI2Y(St)Y PIMF
Conductor | IEC 60228; DIN VDE 0295; EN 60228 Class 2 or Class 5 Electrolytic Bare or Tinned Copper |
Insulation | EN 50290-2-23 PE Compound |
Colour Code | DIN 47100 |
Individual Screen | Pes Tape + Tinned Copper Drain Wire + Pes Tape |
Stranding | Screened pairs in layers |
Wrapping | Pes Tape |
Screen | Tinned Copper Drain Wire + Al-Pes Tape |
Sheath | EN 50290-2-22 PVC Compound |
Sheath Colour | RAL 7001 Grey |
CONDUCTOR RESISTANCE |
INSULATION RESISTANCE (500 V) |
MUTUAL CAPACITY (MAX) |
IMPEDANCE (APPROX.) |
INDUCTANCE (APPROX.) |
CURRENT CARRYING CAPACITY (25°C) |
|||
mm² 0,22 0,34 0,50 0,75 1,0 1,5 2,5 |
Ω/km 79 56 39 26 19,5 13,3 7,98 |
5000MΩxkm | mm² 0,22 0,34 0,50 0,75 1,0 1,5 2,5 |
Ω/km pF/m 70 80 90 90 90 100 120 |
78Ω | 0,67mH/km | mm² 0,22 0,34 0,50 0,75 1,0 1,5 2,5 |
A 2,5 4,5 6,0 13 16 20 25 |
OPERATING VOLTAGE |
TEST VOLTAGE |
BENDING RADIUS |
TEMPERATURE RANGE |
FLAME RETARDANT TEST |
0,22/0,34mm2 = 250V >0,50mm2 = 300/500V |
0,22/0,34mm2 = 1500V 0,50mm2 = 2000V |
10x Cable Ø | -30ºC+70ºC | IEC 60332-1-2 VDE 0482-322-1-2 EN 60332-1-2 |
LI2Y(St)Y PIMF
Conductor | IEC 60228; DIN VDE 0295; EN 60228 Class 2 or Class 5 Electrolytic Bare or Tinned Copper |
Insulation | EN 50290-2-23 PE Compound |
Colour Code | DIN 47100 |
Individual Screen | Pes Tape + Tinned Copper Drain Wire + Pes Tape |
Stranding | Screened pairs in layers |
Wrapping | Pes Tape |
Screen | Tinned Copper Drain Wire + Al-Pes Tape |
Sheath | EN 50290-2-22 PVC Compound |
Sheath Colour | RAL 7001 Grey |
CONDUCTOR RESISTANCE |
INSULATION RESISTANCE (500 V) |
MUTUAL CAPACITY (MAX) |
IMPEDANCE (APPROX.) |
INDUCTANCE (APPROX.) |
CURRENT CARRYING CAPACITY (25°C) |
|||
mm² 0,22 0,34 0,50 0,75 1,0 1,5 2,5 |
Ω/km 79 56 39 26 19,5 13,3 7,98 |
5000MΩxkm | mm² 0,22 0,34 0,50 0,75 1,0 1,5 2,5 |
Ω/km pF/m 70 80 90 90 90 100 120 |
78Ω | 0,67mH/km | mm² 0,22 0,34 0,50 0,75 1,0 1,5 2,5 |
A 2,5 4,5 6,0 13 16 20 25 |
OPERATING VOLTAGE |
TEST VOLTAGE |
BENDING RADIUS |
TEMPERATURE RANGE |
FLAME RETARDANT TEST |
0,22/0,34mm2 = 250V >0,50mm2 = 300/500V |
0,22/0,34mm2 = 1500V 0,50mm2 = 2000V |
10x Cable Ø | -30ºC+70ºC | IEC 60332-1-2 VDE 0482-322-1-2 EN 60332-1-2 |
QUALITY CERTIFICATES
LI2Y(St)Y PIMF
Conductor | IEC 60228; DIN VDE 0295; EN 60228 Class 2 or Class 5 Electrolytic Bare or Tinned Copper |
Insulation | EN 50290-2-23 PE Compound |
Colour Code | DIN 47100 |
Individual Screen | Pes Tape + Tinned Copper Drain Wire + Pes Tape |
Stranding | Screened pairs in layers |
Wrapping | Pes Tape |
Screen | Tinned Copper Drain Wire + Al-Pes Tape |
Sheath | EN 50290-2-22 PVC Compound |
Sheath Colour | RAL 7001 Grey |
CONDUCTOR RESISTANCE |
INSULATION RESISTANCE (500 V) |
MUTUAL CAPACITY (MAX) |
IMPEDANCE (APPROX.) |
INDUCTANCE (APPROX.) |
CURRENT CARRYING CAPACITY (25°C) |
|||
mm² 0,22 0,34 0,50 0,75 1,0 1,5 2,5 |
Ω/km 79 56 39 26 19,5 13,3 7,98 |
5000MΩxkm | mm² 0,22 0,34 0,50 0,75 1,0 1,5 2,5 |
Ω/km pF/m 70 80 90 90 90 100 120 |
78Ω | 0,67mH/km | mm² 0,22 0,34 0,50 0,75 1,0 1,5 2,5 |
A 2,5 4,5 6,0 13 16 20 25 |
OPERATING VOLTAGE |
TEST VOLTAGE |
BENDING RADIUS |
TEMPERATURE RANGE |
FLAME RETARDANT TEST |
0,22/0,34mm2 = 250V >0,50mm2 = 300/500V |
0,22/0,34mm2 = 1500V 0,50mm2 = 2000V |
10x Cable Ø | -30ºC+70ºC | IEC 60332-1-2 VDE 0482-322-1-2 EN 60332-1-2 |
QUALITY CERTIFICATES